Curtis hpd fault. 18 Curtis 1207B Manual 4 — MAINTENANCE After a .

Curtis hpd fault 3. The motor's duty cycle is higher than that specified with the Encoder Fault Threshold parameter and the Controller isn't receiving pulses from the Speed sensor. 2971 1210 MANUAL - Curtis Instruments EN English Deutsch Français Español Português Italiano Român Nederlands Latina Dansk Svenska Norsk Magyar Bahasa Indonesia Türkçe Suomi Latvian Lithuanian český русский • Programmable High Pedal Disable (HPD) and Static Return to Off (SRO) functions. Als globaler Technologieführer bieten wir Systemlösungen für elektrisch- und hybridbetriebene Fahrzeuge und Maschinen an, die den höchsten Qualitäts-, Zuverlässigkeits- und Sicherheitsstandards der Branche angehören. F. 8 — MAINTENANCE. Manuals; Brands; Encoder Fault Setup Menu. • Comprehensive fault detect function monitors main contactor, Curtis PMC 1204 and 1205 controllers are housed in rugged anodized aluminum extrusions that provide environmental protection. Fully compatible with Curtis 1311, 1313, and 1314 programmers for parameter adjustment, tuning, test, and diagnostics Meets or exceeds EEC fault detect requirements; fault detection and diagnostic reporting via a Curtis programmer include (partial list): • Main contactor weld check and driver check • EM brake driver/coil checks Does anyone know where I can find a list of the Curtis Controller Model 1236 fault codes set by OEM/Bad Boy? I have 2 fault codes on my 2013 Instinct. 5 %âãÏÓ 748 0 obj > endobj xref 748 95 0000000016 00000 n 0000006807 00000 n 0000002196 00000 n 0000006944 00000 n 0000007072 00000 n 0000009415 00000 n 0000009470 00000 n 0000009539 00000 n 0000009608 00000 n 0000009676 00000 n 0000009744 00000 n 0000010616 00000 n 0000010682 00000 n 0000010824 00000 n 2. Page 194: Open Armature The max password tries fault is declared when the incorrect password fault has been declared several times. Faulty wiring, crimps, or switches at sequence of KSI, interlock, direction, and Curtis 1244 Manual, Rev. curtisinstruments. Cutoff threshold. Curtis 1515-5201 parameters Electric Club Car. 1268 controller pdf manual download. <br /> After a problem has been diagnosed and corrected, it is a good idea to<br /> clear the fault history file. 11. Electric golf carts: Curtis 1268 Fault Codes: Electric golf carts: All times are GMT -5. KSI, interlock, direction, and throttle Set: HPD (High Pedal Disable) or . Curtis 1298 Manual (Table 5), which also lists possible fault causes and describes the condi- tions that set and clear each fault. 4 = Controller overtemp cutback Fault"". If the fault is corrected while the throttle is still applied, an HPD fault will be issued and driving is disabled until throttle is reduced to neutral. 4626750. 75. Battery Menu. This error can then be compared to the runtime VCL module ID and error code definitions found in the specific OS HPD/Sequencing Fault (flash code 47) is set. 200 KISCO AVENUE MT. *HPD (On) *The primary function of the High Pedal Disable (HPD) Curtis PMC Model 1244 SepEx® programmable controllers provide smooth and seamless regenerative control of separately excited motors. Bad connector crimps or Features include: • Closed-loop speed and torque control for induction (ACIM) motors. Features include: Shop Curtis 325A Series Controller, 0-5K With HPD (For Select Club Car, E-Z-GO Models) at Golf Cart Geeks. 18 Curtis 1207B Manual 4 — MAINTENANCE After a for suggestions covering a wide range of possible faults. 15 Brake Light Driver Refer to the troubleshooting chart (Table 3) for suggestions about possible causes of the various faults. BRAKE OFF Curtis 1230 Manual iii CONTENTS Sequencing Parameters . Throttle input wire open. Set your multimeter to check for DC voltage. E 1 1 1 — OVERVIEW OVERVIEW Curtis 1207/1207A programmable motor speed controllers provide efficient, cost-effective, and simple-to-install control for a variety of small electric vehicles. The switch must be in neutral for several milliseconds to actuate HPD. LED . If a pot fault occurs while the SRO, HPD, Main Contactor Interlock Type, Brake Fault Check, Brake Delay, Brake Hold Voltage, Brake Driver Type, Anti-Rollback Time Emergency Reverse Parameters . 71. 27 High Pedal Disable (HPD) . Diagnostic faults are logged and the history is viewable through a Curtis Model 1307 programmer. C — PROGRAMMABLE SHARED PARAMETERS: Hourmeters. The following steps must be taken to help diagnose a possible cart fault or faulty controller. 2971 4. 32 Brake Fault Check, Brake cont’d ALLOWABLE PARAMETER RANGE DESCRIPTION Fault Code Configures the status LED driver (J1 Pin 17) 1) This is a safety fault caused by a change in certain parameter settings so that the vehicle will not operate until KSI is cycled. Page 190 Curtis AC F4-A Motor Controller – August 2020 Return to TOC Table 18 Fault Code Troubleshooting Chart, cont’d FLASH FAULT NAME POSSIBLE CAUSES SET/CLEAR CONDITIONS FAULT ACTIONS CODE (Curtis Integrated Toolkit™) 12-6 Lower Input Fault The associated fault diagnostic with Set: Faults from the respective/ ShutdownLower Lower_Input information. Replaced controller, brake , all switches on pedals, junction box from harness to new harness, gone through all factory wiring splices, straight wired plug under dash to rule out break in connection, the splices at the orange wire and white wire going to the brake are correct. if controller detects input from throttle when powered up, ie, accelerator is engaged prior to putting cart into forward or reverse, controller will not allow cart to move to prevent runaway . 200 Kisco Avenue Mt. Set: Main contactor driver (pin 6) is either open or shorted. 1. PROGRAMMER . 2,1 Under Voltage Cutoff PWM output disabled. Circuitry for Fault Detection. I reset the code with no success and then unplugged the controller and reconnected and cart works again. KSI, interlock, direction, and throttle Set: HPD (High Pedal Disable) or sequencing fault Faults such as HPD or overtemperature may be caused by operator habits or by overloading. Code 54 and Code 55. 3,1 7 6 WIRING FAULT HPD fault present >10 sec. These are system faults. it does say that it could be a misadjusted pot. Curtis 1298 Manual, Page 117: Table 4: Types Of Led Display KSI and turn it back on to Charge interlock fault disappeared when I wired switch 5 "on" (pin 11). LCD DISPLAY EXPLANATION POSSIBLE CAUSE. This tool costs USD 400. Testing an IQ controller with a multimeter by process of elimination. 2,4 Throttle Fault. Correct start sequence applied The 1243GEN2 controller provides diagnostics information to assist technicians in troubleshooting drive system problems. Faulty or worn speed pot: 3,2 Brake on fault: brake on fault: 1. During normal operation, with no faults present, the Status LED flflashes steadily. We use 5k pots after foot pedal goes bad. 27 Brake Faults . Misadjusted throttle pot 2. We tried to check the on off switch and the forward reverse swich for malfunction but the symthoms were slightly different compared to our fault. PRECHARGE FAULT . Bad connector crimps or Faulty wiring. Circuitry and software to detect faults in the throttle Curtis 1207/1207A Manual, Rev. 45 Page 2- Curtis 1268 - HPD Fault Electric Club Car. 1313 controller pdf manual download. This fault can 3) Bad crimps or faulty wiring be set only when Main Enable = OFF Clear: Correct open or Curtis 1268 - HPD Fault: Electric Club Car: Curtis 1268-5411: Golf Carts and Parts: Curtis 1268-5411 in 2012 Ezgo Express S6 - Tired of getting passed by teenage girls. KSI, interlock, direction, and throttle Set: HPD (High Pedal Disable) or sequencing fault HPD fault present for >10 seconds brake On fault precharge fault brake Off fault. 0 HPD/SRO feature is disabled. If HPD is programmed Off, this protection feature is disabled. • Comprehensive fault detect function monitors main contactor, Curtis 1234E Induction Motor Controller Pdf User Manuals. The time now is 01:59 PM. The Curtis ET-XXX electronic throttle contains no built-in fault detec- tion, • High pedal disable (HPD) function monitors status of the throttle during turn on and prevents operation until the throttle has been returned to neutral. HPD Lockout exists for more . Clear: Correct open or short, and cycle driver . After releasing the throttle the cart runs normal again until when we go full throttle again. About 10 feet into my ride I dropped out. HPD: Allows a safe start by monitoring the status of the throttle. Battery voltage rises above 1. Misadjusted throttle. If a pot fault occurs while the vehicle is moving, the controller will decelerate the vehicle to a smooth stop using the decel rate set by the Key Off Decel parameter. Diagnostic faults are logged and the history is viewable through a Curtis Model 1311 and 1314 programmer. Main Open Delay (0. For example, if a user changes the Throttle Type this fault will appear and require cycling KSI before the vehicle can operate. KISCO, NY 10549 USA TEL (914) 666-2971 FAX (914) 666-2188 CURTIS PMC 235 EAST AIRWAY Features include: Universal logic board supports multiple throttle types and high pedal disable (HPD) It is the responsibil- ity of the OEM to provide appropriate throttle fault detection. These programmable controllers are simple to install, efficient, and cost effective, • Meets or exceeds EEC fault detect requirements • HPD and SRO interlock options ensure proper startup sequence. inputs applied in incorrect sequence. Interlock braking from motor (applied until motor speed approx. Go Figure. The 1243G2 models are available in 4 throttle types. High pedal disable (HPD) [OPTIONAL FEATURE] By preventing the vehicle from being turned on with the throttle applied, Curtis 1268 - HPD Fault: Electric Club Car: Need help wiring Curtis controller 1268-5403: Electric Club Car: Curtis controller mod. Curtis 1268 Manual, Rev. Download Table of Driver 1 (pin 6) is either 2) Dirty connector pins open or shorted. Does anyone have a list and description of the fault codes for the 2021 Club Car Onward Li-Ion HP? I had a fault code 29 this morning for isolation low in the BMS. Electronic Motor Controller. 3k Ω. 2. 26 table 5: Troubleshooting chart (HPD) options. The MultiMode Curtis 1227 is a programmable motor speed controller for permanent magnet Allows smooth stop once it switches off or a fault is detected. If the voltages are still out of range, the controller is at fault and should be replaced. VCL HPD fault comes still when throttle is pressed. Checks for open and shorted faults. The Curtis ET-XXX electronic throttle contains no built-in fault detec- tion, The HPD (High Pedal Detect) fault is detected if the accelerator pedal is already depressed when the key switch is turned to the ON position. If the vehicle is started with an applied throttle, Two Fault Outputs. 2 1244 1 — OVERVIEW Like all Curtis motor controllers, the 1244 offers superior operator control of the vehicle’s motor drive speed. 5 – April 2022 Return to TOC Table 24 Fault Code Troubleshooting Chart, cont’d FLASH FAULT NAME POSSIBLE CAUSES SET/CLEAR CONDITIONS FAULT ACTIONS CODE (Curtis Integrated Toolkit™) 13-13 IMU Failure Check if configured correctly or the Set: Internally set as per NO_ACTION IMU Curtis 1268 - HPD Fault: Electric Club Car: Curtis 1268-5411: Golf Carts and Parts: 1268 curtis: Electric Club Car: Curtis 1268-5411 in 2012 Ezgo Express S6 - Tired of getting passed by teenage girls. See Table 5 for a summary of LED Curtis 1204M/05M/09M/21M Manual iii CONTENTS 1. CE marked as a programmable safety device under EN ISO 13849-1. 1230 Manual, p/n 37092 Rev. Use of a programmer provides diagnostic and test capability as well as configuration flexibility and the ability to easily transfer settings from one controller to another. cpf • High pedal disable (HPD) function monitors status of the throttle during turn on and prevents operation until the throttle has been returned to neutral. If I turn it to much I get a 2,3 fault (hpd) I'm not very familiar with the hpd. 44 Curtis 1210 Manual, Rev. Clean Curtis Model 1226 – September 2019 Return to TOC Understanding the HPD/SRO Function The HPD/SRO safety function protects users from unexpected starts when the interlock input changes from off to on. 1 Proc/wiring fault HPD fault present for 10 sec 1. The controller provides full pot fault protection against open or shorted wires anywhere in the throttle assembly. These are . Main contactor driver failed to close: 3,1 Proc/wiring fault: HPD fault present for 10 sec: 1. Dual Drive Menu. The Curtis 1313-4401 programmer is the most pricy OEM Programmer version and has a greater number of functions than other versions. Interlock Braking 2. 6V to 4. In the following example, the Undervoltage Cutback and HPD Sequencing faults are active: The Fault History menu lists the faults that An HPD fault can be cleared by reducing the throttle demand to less than 25%. The S/N on the cart is PH1034-120909. CURTIS INSTRUMENTS, INC. 0 – 40. DIAGNOSTICS Diagnostics information can be obtained in either of two ways: (1) by reading the display on a 1313 handheld or 1314 PC programmer or (2) by observing the fault codes issued by the Status LEDs. 0 – 8. Curtis 1228 Manual, Rev. 28 Fault Beep The Curtis 1210 MultiMode™ controller is a permanent magnet motor speed 1:DIAGNOSTICS AND TROUBLESHOOTING. The key will make the solenoid click but the cart doesn’t move. 68. 3,3 . 5 = Controller undertemp cutback Fault. S. Designed for 24V / 36V material handling vehicle. FAULT CODE. 1 HPD/SRO enabled for material-handling vehicles. Thanks! Jason HPD/SRO Fault High pedal disable/static return to off Vehicle Disabled Condition cleared. com CURTIS INSTRUMENTS, INC. The pump fault speed parameter sets the maximum pump motor speed in the event the pump disable timer expires or the total disable timer expires; it can be adjusted between 0–100% of Pump Max Speed. LED DIAGNOSTICS . Table 2 STATUS LED FAULT CODES. Electric golf carts: Curtis 1268 Fault Codes: Electric golf carts: All times are GMT Features include: Universal logic board supports multiple throttle types and high pedal disable (HPD) It is the responsibil- ity of the OEM to provide appropriate throttle fault detection. Coil2 Driver Open/Short . 4 Main on fault main contactor driver on fault 1. This manual describes the typical usage of the controller. the HPD is a safety lockout . 30 Sequencing Delay, SRO, HPD, Main Contactor Open Delay, Main Contactor Check Brake Parameters . Static return to off (SRO) fault. 32 Brake Fault Check, Brake Delay, Brake Holding Voltage, Brake Driver Type, Curtis 1204 and 1205 electronic motor speed controllers are designed to provide smooth, Pot fault circuit shuts off controller if pot wires open; The HPD function monitors the throttle position during turn-on and prevents operation unless the throttle has been returned to neutral. 2) Dirty connector pins. Faulty wiring, crimps, or switches at sequence of KSI, interlock, direction, and 5kΩ ±20%. Cycle KSI. this new fault, for os1. The time now is 08:50 AM. 0 s) The EM brake engages unless it already engaged at the completion of interlock braking. Curtis 1207B Manual 21 5 — DIAGNOSTICS &amp; TROUBLESHOOTING Table 2 LED CODE PROGRAMMER LCD DISPLAY TROUBLESHOOTING CHART EXPLANATION only 565. 6 = Under Voltage Cutback Fault. • Full field-weakening capability with ACIM motors. 1 — OVERVIEW. 914. Throttle is normal 5k potentiometer type, and I Curtis 1313-3301, Curtis 1313-2201 and Curtis 1313-1101 are the Dealer Programmer, The IQDM controller response code for HPD is A. Free Shipping on Orders over $100. Motor brake Throttle Voltage Stays stuck on 53%. An HPD fault can be cleared by reducing the throttle demand to less than 25%. 00 USD, 24/36V, 300A, CURTIS Programmable DC SepEx Motor Controller Model 1243-4320. Curtis HPD fault (HPD Type 1) SRO fault. These programmable controllers are simple to install, efficient, and cost effective. 41 Static Return to Off (SRO) Curtis 1244 MultiMode™ controllers are separately excited motor speed control- I have a ezgo cushman minute miser that is giving me a 2,1 fault on the Curtis 1207a controller. Fault Parameters . If the fault is corrected while the throttle is still applied, an HPD fault will be MODEL 12 3 0 MultiMode™ AC INDUCTION MOTOR CONTROLLER &copy; 2007 CURTIS INSTRUMENTS, INC. • Diagnose and troubleshoot faults • Select and use the available programming and diagnostic tools 1 — OVERVIEW The Curtis Model 1351 System Controller provides 26 multi-functions I/O for application in stand-alone or CAN connected systems. Faults such as HPD or overtemperature<br /> may be caused by operator habits or by overloading. CODE . It seem to appear also when some of the input switches is switched "on". Wiring: Fault Outputs . PATENT NO. There are no user serviceable parts in the Curtis 1243. • Emergency reverse (belly button) CURTIS PMC MODEL VOLTAGE ARMATURE RATING FIELD RATING (volts) (amps) (amps) 2 minutes 2 minutes 1244 CURTIS PC programmer 1314-4402: https://www. www. If the fault is corrected while the throttle is still applied, an HPD fault will be issued View and Download HPEVS Curtis 1239 E electrical schematics and documentation online. 00 USD, 24/36V, 200A, CURTIS Programmable DC SepEx Motor Controller Model 1243-4220. Note: All DME scooter applications must have the HPD feature programmed On to satisfy the industry’s safety requirements. This fault can 3) Bad crimps or faulty wiring be set only when Main Enable = OFF Clear: Correct open or CURTIS MOTOR CONTROLLER 1520-5501 48 VOLT 500A 1520-5501 club car IQ 0-5k 1520IQ 1520-5501 IQ, 48V, 500A • Meets or exceeds EEC fault detect requirements with circuitry and software to detect faults in the throttle circuit, • HPD and SRO interlock options ensure proper startup sequence. With a transfer connector (convert kit), the 1266R-5351 controller can easily replace 47 HPD/Sequencing Fault. With ample user code space and the enhanced real-time Curtis The cart ran fine on the jack stands. Page 140 Curtis 1232E/34E/36E/38E & 1232SE/34SE/36SE/38SE Manual, os 31 – May 2017 Return to TOC Table 6 TROUBLESHOOTING CHART cont’d PROGRAMMER LCD DISPLAY CODE POSSIBLE CAUSE SET / CLEAR CONDITIONS EFFECT OF FAULT HPD/Sequencing Fault 1. zero) The EM brake engages unless it already engaged at the expiration of Intk Brake Delay. Curtis 1243GEN2 Manual, Rev. Fully compatible with Curtis 1311, 1313, and 1314 programmers for parameter adjustment, tuning, test, and diagnostics Meets or exceeds EEC fault detect requirements; fault detection and diagnostic reporting via a Curtis programmer include (partial list): • Main contactor weld check and driver check • EM brake driver/coil checks 1,4 Wiring Fault PWM output disabled. TROUBLESHOOTING & BENCH TESTING. High pedal disable (HPD) fault. Re: Curtis 1268 - HPD Fault This issue was resolved 6 years ago and it was not a throttle configuration. There are 2 faults listed in the scanner VCT HPD fault and throttle wiper high, on one side of the pot is a white wire with 12. Trash around the pedal pivot point can keep the pedal from going all the way up, as can a weak or broken return spring. 43. Typical applications include golf carts and small utility vehicles. Throttle dead-band: 0V to 0. B v Hourmeter Parameters . CONTROLLER MAINTENANCE. Release Lowest unit price 289. 0 kΩ. Solenoid klicking normal. A P P L I C AT I O N Curtis PMC SepEx® controllers are designed for small material Dynamic pot fault detection (open/short wiring fault detection). Wiring details are provided in Section 3. Kisco, NY). Other controller: Same effects as this controller. The IQDM controller response code for HPD is A. 2188 Curtis 1268 - HPD Fault: Electric Club Car: Throttle fault on the Curtis Controller 1268: Electric golf carts: RXV Fault Codes - CURTIS CONTROLLERS: Electric EZGO: Curtis 1268 Fault Codes: Electric golf carts: curtis controller fault code: Electric EZGO: All times are GMT -5. 1 Curtis . 45 Adjust Hours High . 1 Curtis Instruments GmbH, gegründet 1989 in Paderborn, ist eine Tochtergesellschaft der Curtis Instruments, Inc. 3 to 7. Fully programmable analog throttle input for precise speed control with a variety of signal sources. 1 Curtis 1207B electronic motor controller and 1311 handheld programmer. These same fault codes will also be flashed by the external fault LED (connected to Pin 22), if one is included in the system. HARDWARE INSTALLATION. ShutdownThrottle. If the controller detects a fault, a 2-digit fault code is flflashed until the fault is Refer to the troubleshooting chart (Table 3) for suggestions about possible causes of the various faults. When the HPD box is checked the HPD feature is enabled. Vehicle Menu. Steps: Locate the throttle adjustment settings on your Curtis controller. 4v and the other side a black wire with 9. 1204M / 1205M Manual 1204M/1205M Manual, p/n 53113 Rev. com/product/1314-4402. 16 Wiring: Contactor Drivers High Pedal Disable (HPD) . Table 3 TROUBLESHOOTING CHART. There were 4 things that it showed , in this order : HPD/Sequencing Fault Undervoltage Cutback Curtis 1268 - HPD Fault: Electric Club Car: Carryall 232 Speed Sensor Fault/ Anti tamper Fault: Electric Club Car: RXV Fault Codes - CURTIS CONTROLLERS: Electric EZGO: Curtis 1268 Fault Codes: Electric golf carts: All times are GMT -5. F Curtis Model 1226 – September 2019 Return to TOC You must heed the following warnings: Working on electrical systems is potentially dangerous. Fig. 1) Open or short on driver load. This fault can be set only when Main Enable = ON . 28 Seat Lift Brake Faults . com Curtis PMC 1204 and 1205 controllers are housed in rugged anodized aluminum extrusions that provide environmental protection. The time now is 09:22 AM. DESIGN OF CURTIS 1200 SERIES CONTROLLERS PROTECTED BY U. Interlock Braking The Curtis Model 1239E provides energy efficient control of asynchronous AC induction motors performing on-vehicle traction drive duties. We get asked a lot how to troubleshoot a Curtis 1510 or 1515 controller on a DS IQ, or Precedent with Excel or ERIC system without the handheld Curtis scan tool. The 1243GEN2 controller has two fault outputs, Curtis 1234E Induction Motor Controller Pdf User Manuals. View and Download Curtis 1313 user manual online. C. under normal circumstances, releasing the accelerator and reapplying would release the HPD Anti-tiedown fault. The problem is a physical difference in the pin-out between IQ and Excel controllers throttle return (negative) pin/connection and how it is used in the Excel cart harness. 00 USD for a set of 1243-4320 controller assemblage, 24V / 36V - 300A, with Control Handle and Installation Kit. 32 . Motor encoder failure. An expanded section explains the CANbus emergency message, including several examples. 1 = encoder signal seen but step size not auto-detected; set up Encoder Steps manually". Electric Club Car Electric DS, and Precedent golf cars FSIP-76-1243-4224 : Curtis Controller 24/36V 200A (0-5V) SX CONTROL #1243-4224. A: December 2009 CURTIS INSTRUMENTS, INC. 1313 Handheld Programmer Manual Rev. Curtis 1268 - HPD Fault: Electric Club Car: Throttle fault on the Curtis Controller 1268: Electric golf carts: RXV Fault Codes - CURTIS CONTROLLERS: Electric EZGO: Curtis 1268 Fault Codes: Electric golf carts: curtis controller fault code: Electric EZGO: All times are GMT -5. Throttle input wire shorted to B+ or B-. 2971 Fax 914. The 1243-4320 controller is the new generation separately excited motor speed controller, designed for use in a variety of small industrial vehicles and in material handling equipment. 3) Bad crimps or faulty wiring . 1) This is a safety fault caused by a change in certain parameter settings so that the vehicle will not operate until KSI is cycled. Powerful Safety Features • Meets or exceeds EEC fault detection requirements. htmCURTIS handheld programmer 1313-4331: https://www. It turned out to be the controller. %PDF-1. the controller is at fault and should be replaced. OVERVIEW. Protect yourself against uncontrolled Adjusting the settings was a straightforward fix. 6V. High pedal disable (HPD) function monitors throttle status during turn-on; Thermal protection and compensation circuit provides both under-temperature and over-temperature cutback; Undervoltage cutback function protects against low battery voltage; Pot fault circuit shuts off controller if pot wires open; Simple installation with no adjustments A DIVISION OF CURTIS INSTRUMENTS, INC. On a display mounted remotely, Refer to the troubleshooting chart (Table 3) for suggestions about possible causes of the various faults. To meet EEC requirements, HPD The motor's duty cycle is higher than that specified with the Encoder Fault Threshold parameter and the Controller isn't receiving pulses from the Speed sensor. You may also write to us at: Club Car, LLC, P. Motor Temperature Control Menu. These controllers are fully programmable by means of a Curtis program-ming device. 4. If a pot fault occurs while the vehicle is HPD fault present for >10 seconds brake On fault precharge fault brake Off fault. 666. EM Brake PWM. Electric golf carts: Curtis 1268 Fault Codes: Electric golf carts: All times are GMT 2 1244 1 — OVERVIEW Like all Curtis motor controllers, the 1244 offers superior operator control of the vehicle’s motor drive speed. Curtis PMC 1204X/1205X/1209/1221 Manual Page 45 HPD feature. Service timer or disable timer expired. Features include: %PDF-1. HPD FAULT CURRENT SENSE FAULT * HARDWARE FAILSAFE * EE CHECKSUM FAULT (not used) BATTERY DISCONNECT FAULT * a a a a a aa aa aa aa aa a aa aaa aaaa aaaaa a aa aaa 2. If the fault is corrected while the throttle is still applied, an HPD fault will be Fully programmable via Curtis hand-held tools or Curtis PC programming software model kits 1314K. F 43 &curren;&curren; main contactor driver Off fault main contactor fault main contactor driver On fault HPD fault present for &gt;10 seconds brake On fault precharge fault brake Off fault HPD (High Pedal CURTIS 1307 PROGRAMMER PROC/WIRING FAULT HPD fault present >10 seconds SPD LIMIT POT FAULT Speed limit pot input voltage out of range THERMAL CUTBACK Cutback, due to over-/under-temperature THROTTLE FAULT 1 Throttle input voltage out of range DIAGNOSTICS revised 7/05. The fail codes are: HPD Motor Stall Does anyone know where I can find a list of the Curtis Controller Model 1236 fault codes set by OEM/Bad Boy? I have 2 fault codes on my 2013 Instinct. Home: FAQ: Donate: Who's Online : Buggies Gone Wild Golf Cart Forum > Golf Cart Repair and Troubleshooting > Electric Club Car: Curtis 1268 - HPD Fault User Name: Remember Me? Password: Register: Golf Cart Pics: Site Curtis 1268 Manual, Rev. PMC 1204 Series controller pdf manual download. 2,3 HPD. Curtis 1204 and 1205 electronic motor speed controllers are designed to provide smooth, silent, cost-effective control of motor speed and torque on a wide variety of industrial electric vehicles. 5V (fault condition above 6V). Curtis PMC 1204/1205 Manual 7. Make sure the pedal switch contacts open when pedal is up. 8v at the relay there is TPV 72v on 3 of the posts and 44v on the pink wire for driver 2 settings (which seams odd). High pedal disable (HPD) [OPTIONAL FEATURE] By preventing the vehicle from being turned on with the throttle applied, View and Download Curtis PMC 1204 Series manual online. Add to my manuals. 1,4 Wiring Fault PWM output disabled. To ensure full rated power, the controller should be fastened to a clean, flat metal surface with four 6 mm (1/4") diameter screws, using the holes 1243 Curtis Controllers. Curtis 1243 Generation 2 MultiMode™ controllers are separately excited motor speed controllers designed for use in a variety of small industrial vehicles and in material handling equipment. View and Download Curtis Instruments MultiMode 1230 manual online. 2 controller. The time now is 06:53 AM. . Page 1 2009-2011 Electric Precedent Maintenance and Service Manual IQ System and Excel System Vehicles Manual Number 103472701 Edition Code 0309C1110B; Page 3 If it appears that a service question is not answered in this manual, please contact your nearest authorized Club Car dealer or distributor for assistance. errors. txt) or read online for free. If the Normally caused by turning off Motor Characterization Test Enable before running the test. Model 1205 electronic motor controller. CURTIS 1307 PROGRAMMER PROC/WIRING FAULT HPD fault present >10 seconds SPD LIMIT POT FAULT Speed limit pot input voltage out of range THERMAL CUTBACK Cutback, due to over-/under-temperature THROTTLE FAULT 1 Throttle input voltage out of range DIAGNOSTICS revised 7/05. The diagnostics information can be obtained by observing the appropriate display on the programming device, the fault message displayed on the Spyglass gauge, the fault codes issued by the Status LED, or the fault display driven by the controller’s fault outputs The only time a Curtis RXV has given an encoder fault for us was when one of the pins got pushed out when we had to replace one and didn't notice it. . E 5 2 — INSTALLATION & WIRING: Controller programmer into its connector, and (2) that the built-in Status LED is visible only through the view port in the label on top of the controller. From the Fault counter sub heading; Main contactor did not close 5,Brake wiper3,HPD Sequencing fault 4, Undervoltage cutback 34, controller overcurrent 11,Motor temp faults 1, Stall detected/Enconder Fault 14,EM Brake failed to set 8, Main coil missing 76, EM Brake test failed 8, Throttle zero check 1, Supervisors comms 1, trigger a fault condition. The fault Table 11 has been updated to include the 3100R and Status Beacon fault codes, the Fault Actions, and the applicable CANopen Emergency Message Category, by bit. Features include: MODEL 12 3 0 MultiMode™ AC INDUCTION MOTOR CONTROLLER &copy; 2007 CURTIS INSTRUMENTS, INC. Allows modulation of auxiliary driver output. An advanced MOSFET power section provides very high efficiency, silent operation and reduced motor and battery losses. See Table below for a summary In Fault Code format (fault code parameter On), the two fault outputs operate independently. 8, may appear as the EMR HPD fault. KISCO, NY 10549 USA TEL (914) 666-2971 FAX (914) 666-2188 CURTIS PMC 235 EAST AIRWAY . No. ShutdownDriver2. F 1 1 — OVERVIEW OVERVIEW The Curtis 1228 MultiMode™ controller is a permanent magnet motor speed controller designed for use in mobility aid scooters and other small electric High pedal disable (HPD) function monitors throttle status during turn-on; Thermal protection and compensation circuit provides both under-temperature and over-temperature cutback; Undervoltage cutback function protects against low battery voltage; Pot fault circuit shuts off controller if pot wires open; Simple installation with no adjustments Curtis 1206 HB This sheet is provided to aid in the installation of your remanufactured CURTIS controller. • Emergency reverse The controller provides full pot fault protection against open or shorted wires anywhere in the throttle assembly. SERVICE TOTL HPD sequencing and EM Brake Missing Faults on RXV Electric EZGO Curtis Controllers Model 1227. Helps in preventing runaway conditions and monitors components such as the battery, and a contactor, among others. Curtis 1239 E controller pdf manual download. Passive regen provides vehicle speed control at any throttle position when going down ramps. BRAKE OFF Meets or exceeds EEC fault detect requirements with circuitry and software to detect faults in the throttle circuit, MOSFET drive circuits, and driver outputs. 0 s we have installed two controllers due to believing it was a controller problem as by the controller rebuilders. Electric golf carts: Curtis 1268 Controller: Electric Club Car: All times are GMT -5. 6591 Sierra Lane, Dublin, CA 94568 TEL 510-828-5001FAX 510-833-8777 High Pedal Disable (HPD) ISO Pot Fault. 1268-5403: Golf Carts and Parts: Curtis 1268 Controller: Electric Club Car: Looking for Curtis Controller 1268-5403: Golf Carts and Parts: All times are GMT -5. KSI, interlock, direction, and throttle Set: HPD (High Pedal Disable) or sequencing fault Fault Parameters . Curtis 1207B Manual 21 5 — DIAGNOSTICS &amp; TROUBLESHOOTING Table 2 LED CODE PROGRAMMER LCD DISPLAY TROUBLESHOOTING CHART EXPLANATION (Curtis 1311 and 1314) enable the user to set parameters, conduct tests, and obtain diagnostic information quickly and easily. 3) Bad crimps or faulty wiring. If throttle input is received before interlock Limited Operating Strategy (LOS) control mode has been activated, as a result of either an Encoder Fault (Code 36) or a Stall Detect Fault (Code 73). It has an Advanced DC Motor, P/N EJ4-4001-LR3. LIVERMORE, CA 94551 USA TEL (925) 961-1088 Fig. View online or download Curtis 1226 Manual A DIVISION OF CURTIS INSTRUMENTS, INC. 3,4 . Two fault outputs provide diagnostic information for dash mounted displays. No at-tempt should be made to open, repair, or otherwise modify the controller. Curtis 1268 - HPD Fault: Electric Club Car: Carryall 232 Speed Sensor Fault/ Anti tamper Fault: Electric Club Car: RXV Fault Codes - CURTIS CONTROLLERS: Electric EZGO: Curtis 1268 Fault Codes: Electric golf carts: All times are GMT -5. KISCO, NY 10549 USA TEL (914) 666-2971 FAX (914) 666-2188 CURTIS PMC 235 EAST AIRWAY BLVD. LED CODES EXPLANATION HPD fault present for >10 sec. 26 KSI SRO Enable Mode After KSI Overvoltage Low Voltage Warning Option Output Driver High pedal disable (HPD) and static return to off (SRO) interlocks prevent vehicle runaway at startup Page 149 Curtis 1239E-1269E Manual, os 37. Model 1204 has identical connections. These programmable controllers are simple to install, efficient, and cost effective, I have replaced about everything I can think of on the cart. Faults such as HPD or overtemperature may be caused by<br /> operator habits or by overloading. 4 Throttle Types. I cleared the codes and tried again to get no HPD this time but still Main Drop Out and Low Battery Voltage. Faulty or worn throttle pot 3. 3,2 . Hourmeter Reset Service Times. pdf - Free download as PDF File (. LED output for easy system troubleshooting via flash codes. Sign In Upload. Release Page 1 2009-2011 Electric Precedent Maintenance and Service Manual IQ System and Excel System Vehicles Manual Number 103472701 Edition Code 0309C1110B; Page 3 If it appears that a service question is not answered in this manual, please contact your nearest authorized Club Car dealer or distributor for assistance. I am curious as to what happened and what to do to keep it from happening again. Checked codes and got a HPD, Main Drop Out and Low Battery Voltage. Faulty If a fault is active, the fault names are contained in the menu panel’s top node and are identified by icons. 13 Fault Detection The Curtis PMC 1208C electronic DC motor speed controller is designed for permanent magnet motor applications in mobility aids, We get asked a lot how to troubleshoot a Curtis 1510 or 1515 controller on a DS IQ, or Precedent with Excel or ERIC system without the handheld Curtis scan tool. com/product/1313-4 Curtis 1212 Controller Flash Codes Applies to: Kite Scooters (from 2011) Diagnostics Available in a 45A version. The 1243-4220 controller is the new generation separately excited motor speed controller, designed for use in a variety of small industrial vehicles and in material handling equipment. • Shorted and open throttle faults are detected with proper controller shutdown. Faults such as contactor faults may be the result of loose wires; contactor<br /> wiring should be carefully checked. 2 = motor temp sensor Fault. More Features ☞ Like all Curtis motor controllers, the 1207B models offer superior operator control of the vehicle’s motor drive speed. When it happens in reverse the beep stays on. Carefully modify the throttle input values for When I run diagnostics I still get HPD, when it not running monitor shows throttle from 0 to 100 as I press the pedal. pdf), Text File (. B Page 12: The Nine Menus 3 — MENU ORGANIZATION The Diagnostic faults are logged and the history is viewable through a Curtis Model 1311 and 1314 programmer. It has the Curtis conversion kit. Values outside this range will trigger a fault condition. 3 = motor temp hot cutback Fault. Faults such as<br /> contactor faults may be the result of loose wires; contactor wiring should be<br /> carefully checked out. If I unplug the MCOR, clear the codes then replug it. Bad connection at battery or controller. 00 USD, free shipping. Battery voltage at or below . Powerful Safety Features Meets or exceeds EEC fault detection requirements. called hyster ,they came in and hookup laptop,cleared the 41 code and saw that motor was pulling 650 to 700 amps, I pulled the motor 47 HPD/Sequencing Fault. Curtis PMC 1204/1205 Manual 30. • Programmable High Pedal Disable (HPD) and Static Return to Off (SRO) functions. High pedal disable (HPD) function monitors throttle status during turn-on; Thermal protection and compensation circuit provides both under-temperature and over-temperature cutback; Undervoltage cutback function protects against low battery voltage; Pot fault circuit shuts off controller if pot wires open; Simple installation with no adjustments The Curtis Model 1216 is a highly cost-effective hydraulic pump controller for use with Throttle active range: 0. Curtis 1268 Manual, Curtis 1268 Fault Codes Portable With Convenient and their corresponding controller responses for a Club Car IQ System golf cart. original problem was little to no travel and no codes, constant testing caused controller to overheat- gave code 41. • Power off decel provides a controlled deceleration if the key switch is turned off while driving. 15 Brake Light Driver Curtis 1204 and 1205 electronic motor speed controllers are designed to provide smooth, Pot fault circuit shuts off controller if pot wires open; The HPD function monitors the throttle position during turn-on and prevents operation unless the throttle has been returned to neutral. Faulty or worn speed pot PUMP FAULT SPD. Circuitry and software to detect faults in the throttle circuit and MOSFET drive circuits help prevent unsafe operation. Download Table of Contents Contents. Throttle input Diagnostics information can be obtained by observing the fault codes issued by the Status LED’s or as displayed on the Spyglass. Bad connector crimps or Faulty wiring Re: Curtis 1268 - HPD Fault This issue was resolved 6 years ago and it was not a throttle configuration. LIVERMORE, CA 94551 USA TEL (925) 961-1088 Intermittent 'Forward Input - Off' issue on Curtis 1520: Electric Club Car: curtis 1520-5501 controller: Golf Carts and Parts: Need Wiring Diagram for Curtis 1520-5501: Electric Club Car: Curtis 1520-5501 Sepex not Powering Key Switch Up: Electric Club Car: Curtis 1520 48volt controler Wiring help needed: Electric Club Car View and Download Curtis 1313 user manual online. Code Fault Cause; 11: Hardware Failsafe : 1. Yes. Status LED fault codes . Curtis PMC 1297 Manual 61. View online or download Curtis 1234E Induction Motor Controller Manual. 0 RevA – May 2021 Return to TOC Table 6 TROUBLESHOOTING CHART cont’d CODE PROGRAMMER LCD DISPLAY POSSIBLE CAUSE SET / CLEAR CONDITIONS (status#,bit) EFFECT OF FAULT HPD/Sequencing Fault 1. Under Voltage Cutback the programmed Under Voltage threshold. Faulty or worn speed pot View and Download HPEVS Curtis 1239 E electrical schematics and documentation online. Curtis 1207B Manual 21 5 — DIAGNOSTICS &amp; TROUBLESHOOTING Table 2 LED CODE PROGRAMMER LCD DISPLAY TROUBLESHOOTING CHART EXPLANATION errors. Curtis 1266R-5351 controllers are separately excited motor speed controllers designed for use in a variety of transport vehicles. KSI, interlock, direction, and throttle inputs applied in incorrect sequence. When a fault is present, the Fault 1 driver (Pin 2) provides a pulsed signal equivalent to the The 1238 manual has code 47 as an HPD sequencing fault and lists the following possible causes: 1. Keyswitch. 8. than 10 seconds. Curtis Controller Fault Code Translator Full List Of Faults For Motor Controller Model 1268. Put a different one in and it worked. Instead of using HPD:Worklog directly for searching like this, use the purpose built join between HPD:Help Desk and HPD:Worklog. <br /> Curtis 1268 - HPD Fault: Electric Club Car: Throttle fault on the Curtis Controller 1268: Electric golf carts: RXV Fault Codes - CURTIS CONTROLLERS: Electric EZGO: Curtis 1268 Fault Codes: Electric golf carts: curtis controller fault code: Electric EZGO: All times are GMT -5. Select Motor Controller Model For Full List Of Fault Codes Whenever a fault is encountered and no wiring or vehicle fault can be found, shut off KSI and turn it back on to see if the fault clears. Everything seems to be correct but the throttle range is between 30% and 44% at rest or when foot switch is a acctivated. Handheld Programmer. HPD (High Pedal Disable) means if the pedal does not return to the full upright position, the cart won't run. F 1 1 — OVERVIEW OVERVIEW The Curtis 1228 MultiMode™ controller is a permanent magnet motor speed controller designed for use in mobility aid scooters and other small electric Curtis 1268 - HPD Fault: Electric Club Car: Curtis 1268-5411: Golf Carts and Parts: Curtis 1268-5411 in 2012 Ezgo Express S6 - Tired of getting passed by teenage girls. 33 Wiring Check, Speed, Direction Interlock, Time Limit, Accel Rate, Switch Curtis 840 Spyglass display Lowest unit price 272. Kisco, New York 10549 USA Tel. 1Curtis 1268 electronic motor controller. sequencing fault caused by incorrect . Sequencing Delay, SRO, HPD, Main Contactor Interlock Type, Main Contactor Open Delay, Main Contactor Check Brake Parameters. Curtis 1226 Pdf User Manuals. Motor too hot. Only one fault is indicated at a time, and faults are not queued up. noco-evco. BRAKE ON FAULT brake On fault . Vehicle speed is controlled and limited at top end via motor field control. Figure 2 The Curtis enGage® II Curtis 1268 - HPD Fault: Electric Club Car: Curtis 1268-5411: Golf Carts and Parts: Curtis 1268-5411 in 2012 Ezgo Express S6 - Tired of getting passed by teenage girls. B. 0kΩ. cpf (parameter settings) files. Jack up vehicle and retest to confirm diagnosis. To meet EEC requirements, HPD must be programmed to Type 1 or Type 2. Broken throttle pot or throttle mechanism. HPD fault detection can be turned off by setting the HPD Type to 0. Interlock Brake Delay (0. 3 Environmental protection provided by rugged anodized aluminum extruded housing. In 370. What else is there that could be causing to controller to See Monitor menu -> Controller: VCL Error Module and VCL Error. 66. It's called HPD:Search-Worklog, you can navigate there directly or go by Incident Management Console -> Advanced Search and then select search by work log. Motor Feedback 2-Sin/Cos Menu. I pulled it down to take a test drive. Faults such as HPD or overtemperature may be caused by operator habits or by overloading. Circuitry and software to detect faults in the throttle circuit and Curtis 1228 Manual, Rev. GEN. Throttle input impedance: 14. Push input and a Push-too-Fast function which ‘ loads’ the motor to prevent excessive motor speeds when the EM brake is off. So I figured I'd post this guide on here for people to reference. If it does not, shut off KSI and remove the 35-pin connector. Easy fix. (Mt. Main contactor driver failed to close 3. 67. Consult Curtis Instruments's entire 1243/1243 CAN catalogue on DirectIndustry. The checks are meant to diagnose potential faults that could cause the controller to fail. Correct start sequence applied Curtis Controller Fault Codes. 8 Keyswitch (HPD) Option. View and Download Curtis 1268 manual online. Curtis 1268 - HPD Fault Electric Club Car. Shop Curtis 325A Series Controller, 0-5K With HPD (For Select Club Car, E-Z-GO Models) at Golf Cart Geeks. B 51. Generic-with-Curtis-1268-5403-Control. 76. 7 — DIAGNOSTICS & TROUBLESHOOTING. O. KSI, interlock, direction, and throttle Set: HPD (High Pedal Disable) or sequencing fault Set the Lift BDI Lockout and Hyd Inhibit Type (HPD) parameters as required by the application. The overall pot resistance should be 4. HPD/Sequencing Fault Undervoltage Cutback Controller Overcurrent Comms Supervision So i cleared all faults, then after it did it again, i went home and plugged in the curtis scanner. Controllers must be kept clean and dry, however, to ensure long life. 5 %âãÏÓ 521 0 obj > endobj xref 521 53 0000000016 00000 n 0000004379 00000 n 0000001356 00000 n 0000004533 00000 n 0000004661 00000 n 0000005107 00000 n 0000005246 00000 n 0000005379 00000 n 0000005447 00000 n 0000005513 00000 n 0000005980 00000 n 0000006006 00000 n 0000006158 00000 n 0000008206 00000 n Curtis 1268 Fault Codes Electric golf carts. This document provides instructions for performing checks on a golf cart's motor, solenoid, and wiring harness before installing a remanufactured CURTIS controller. The time now is 05:55 PM. 7 = severe Over 3. Action: Shutdown EM Brake Shutdown Throttle Shutdown Motor: 1. Programmable isolation monitoring and fault detection. Supports multiple throttle types and high pedal disable (HPD) options. C: October 2007 CURTIS INSTRUMENTS, INC. Upon installation, you may encounter problems that may, or may not, be due to a faulty controller. 70. Motor brake manually released 2. The High Pedal Detect (HPD) fault is identified if the accelerator is depressed already when Curtis Controller Fault Code Translator Full List Of Faults For Motor Controller Model 1268. I have a Curtis Hand Held programmer, and when plugged in It's getting a HPD fault and a throttle fault. Cheap $40 unit from Main contactor driver fault: 2,4 Main on fault: main contactor driver on fault: 1. D iii CONTENTS 1. PWM output disabled. The Curtis Model 1226 Motor Speed Controllers provide efficient, optimal control of permanent magnet drive motors for battery powered vehicles. Controller defective: 12: Throttle 1: 1. 1 faults caused by loose wires, or faults caused by operator errors. 36: Encoder . Page: 1/6 ISO Pot Fault. An analog or digital volt ohm meter (VOM Page 251 Curtis AC F2-A, F4-A, F6-A Motor Controllers – FOS 4. But an oscilloscope has indeed come in handy for the older Danaher cars with avoiding needlessly pulling the motor and replacing it when it was not the real issue. Throttle pot defective : 13: Speed Sensor: 1. dqsjpfx ftb vazykuoov ypor nrzz pbekua gatcjbm rkjvsd ossd shhu