Arduino modbus rtu master programming It is based on a controller-peripheral (formerly known as master-slave) architecture and communication between This is an Arduino library that implements the master/client logic of the Modbus RTU protocol. how can i save data directly in float here. Recommended Modbus Master: Modbus RTU library on Serial3 using module. Using the Arduino library ArduinoModbus. There are a few differences in the APIs depending on the transport, but the majority of the functions are the same for both. Supports Modbus TCP Security for ESP8266/ESP32. Thank you very much!!! Are you sure you know what Modbus is? You cannot send a value to the master, the master always must request it from the slave, the slave is only allowed to answer. Arduino-based Modbus RTU to Modbus TCP/UDP gateway with web interface. Slave device: ID 1, address 145. Programming Questions. Networking, Protocols Reading register of Modbus RTU sensor with Arduino Uno using TTL-RS485 converter. For example, to write or read any value from the master, the Modbus RTU must receive an unsigned 16-bit integer array and its length from the Master Modbus. So i am guessing i do got an connection towards the slave. Compatibility. The PLC seems to be waiting for a connection, but for some reason the esp is not successful in establishing one. If I just send Hi, I am a newbie to Modbus and RS-485. Can some body help me to go further on reading the data over Modbus RTU Hodling addresses to read data from HMI or PLC? Programming. So start with an easier task, learn how to write code for the Arduino. I have one master device, that is communicating with few slaves. Pretty simple project. #include <Controllino. The sensor uses a modbus protocol for communication (RS 485). It works by receiving a input of 1 to 12 through either the serial monitor or a bluetooth device. I have tested this module with other example (function 03) reads found in the manufacturer's instructions using Arduino Nano with MAX485 module, Most complete Modbus library for Arduino. T0101 it should send "1" to the arduino and run the code to do the change. 1. A library that allows your Arduino to communicate via Modbus protocol, acting as a slave (master in development). The function returns an incorrect value and I don't know why. I tried several Modbus Master Simulation tools, with all possible connection config options, but I always get a timeout. i've tried the scenario where the information is 32 bits and not 16 bits. The protocol is widely used because it is robust and easy to implement. We help you if you have a problem but we don't do your complete project. You can stay with Modbus or you can simply create your own protocol. Now i have sensor output in float value & buffer it stores in int value. microdigisoft August 7, ModbusRTUMaster. h using this example I'm working with a 32-Input Modbus module, simply trying to poll the inputs to read On states (0=off, 1=on) of a holding register in this example. How could For now i can send data just between master and first slave. SensorModbusMaster. 39 Most of the time you will connect the arduino to a master via serial 40 using a MAX485 or similar. I am able to communicate on MODBUS RTU protocol with DUE board. i confirmed this on my scope but the instant DE is made high, it immediately goes low at the same time the TX transmission begins, and it seems to be that flush() is not blocking as it should. 1: 1051: I have facing issues in the above code can anybody help me through it. The Libraries Home / Programming / Library / SensorModbusMaster . the parameters i want to use MODE-RTU SLAVE ADDRESS-2 DATA BIT-8 PARITY-NONE ADDRESING FLOW RATE-1800 LENGTH Hi all, I'm working on a project where my Arduino is used as a Modbus RTU master to control a stepper motor. If not connected TX blinks 10 times, and stops (as programmed). 4: 267: November 11, 2023 Home ; Beacuse it's my first time whit the modbus. It has several pages / blogs / videos referring to the things of the PDA Control or the Trialcommand (which are the same library), but I could not make it work fine. h library, but it doesn't seem to work correctly. I have two steppers (ID1 and ID2) that I'd like to give a command (move to a specific position). zip. snauwy May 10, 2023, 11:03am 1. Arduino Forum Nano with Modbus RTU. A Modbus command contains the Modbus address of the device it is intended for. I have Hi, I want to read some data from a pyranometer using Modbus, an arduino mega and a max485 converter (to create a rs485 grid, the complete proyect includes several pyranometer connected to the same port of the arduino). In project each slave will Dear all,. Sara Damiano. The RTU variant communicates over serial lines such as UART, RS-232, or RS-485. Here Arduino Uno has two push buttons and a potentiometer to send the This is an Arduino library that implements the master/client logic of the Modbus RTU protocol. 6: 3395: May 6, 2021 MODBUS RS485 communication , response for masters request. I'm trying to implement Writing Multiple Registers (0x10) using the Modbus Structure on a Controllino Mega MCU. I know that 0x00 is value off. Since I don't have Learn: How to use Arduino Modbus library, what is Modbus, why needs Modbus, how Modbus works, how many types of Modbus, and Modbus RTU/ASCII, Modbus TCP. */ /* Hi, I am working on my first project. Only not being able to make some data visible. Using Arduino. Hello, I want MODBUS RTU master and slave. I use this library to do Modbus RTU, it has examples of how to use it. When I try to use 1 slave, the data is Modbus is a Serial Communication protocol which was discovered by Modicon in 1979 and it is used for transmitting data over serial lines between the industrial electronic devices. 0. Hi, I have a modbus RTU pH and Temperature sensor that I wish to read with Arduino Mega as add on to my existing program. I need help from those who have This is not a free programming service. For the tutorial example, we will use the following properties for client Opta™: Baud Rate: 19200 b/s; Serial Mode: N,8,1 (No parity, 8 data bits, 1 stop bit) Arduino PLC IDE - Opta™ Modbus RTU Client Configuration. I am new to Arduino coding. I want to write the value read from the hc-sr04 sensor on the slave device to the master device as boolean according to a thresold value. Programming Arduino UNO for RS-485 MODBUS Slave. I am trying to setup a connection between an Arduino Nano and an USB port at the PC. I am able to transmits data, and the pyranometer responds as Configure The Modbus RTU Communication. This system's strength is its flexibility. I didn't see a "guides" section and this doesn't really meet many standards in way of a guide, but I thought it could really help someone get started, esp We have executed ESP32 with MODBUS RTU RS485 Protocol Using Arduino IDE . Communication is working but the data i am sending is not right. Hi everyone, I want to Modbus Master (arduino uno), and simple modbus slave pressure sensor. i have totally 25 current parameter ; 1 voltage ; 1 temprature sensor ; All the values are in float only. I want to describe what I define as "plain simple to use": Has an example-code where the master-code directly fits to a given slave-code which means use serial1 for the data-exchange flash master Have a good day. 4)Install Modbus Master simulator software in my PC 5)connect my PC to Arduino board 6)Launch Modbus Master simulator ---works perfect--- Then I connect TX0, RX0 to my serial cable , serial cable to USB I have two mega arduino and want to them communicate with modbus rtu toghter , i use below link circuit for this : but dont work!! while they work in simple rs485 and without modbus with same above link code !? my cod 1. All the other devices are slaves and answer requests and commands. org. The master can send information-data, to the slaves, or read info-data from them. This library is designed to use an Arduino as a modbus master to communicate with a sensor/slave via modbus RTU. The holding register 0 value should be changing from 1,2,,10 every 2 seconds. I bought a cheap rs485 converter MAX485-Module-RS-485-TTL The settings from the sensor datasheet are the following: Baud Rate: 9600 Parity: None Data Bits: 8 Stop Bits: 1 Model: 1-Word I know what Baud Rate, data bit and stop bits are but I I have been working on simple modbus communication but, I haven't succeeded. IDE 1. 4. A library that allows your Arduino board to communicate via Modbus protocol, acting as a master, slave or both. This library implements function codes 1 (Read Coils), 2 (Read Discrete Inputs), Modbus RTU (RS485) is a popular communication protocol used in industrial automation applications for communication between devices. The problem is that i not able to implement the library into the code . All of that said, the Generic Modbus catalog in PLC IDE works very well in the Modbus RTU applications I've tested it in. The Arduino Nano shall act as slave, the PC as master (for testing). MODBUS. At the moment I've one master reads an analogue channel from one slave, I would like to add more slaves (another 3), The part I'm not sure is how to get the master to read from the other 3 slaves. h> /* The example will use packet1 to read a register from address 0 (the adc ch0 value) from the arduino slave (id=1). But when trying with esp as client and PLC as server, it's not working. I made a very simple test program and everything runs fine, the master communicates correctly with the slave, i Hi all. With the Arduino, you have full custom control over the program design allowing you to create very lean and very efficient devices for very specific purposes. h" /* Usage of ModBusRtu library allows you to implement the Modbus RTU protocol in your sketch. Thanks for help. - emelianov/modbus-esp8266 Hello, I'm doing a modbus RTU communication protocol the function for calculating the CRC I came across a strange effect. I was able to get it running as a server, communicating with Siemens 1500 PLC as a client. h> /* Usage of CONTROLLINO library allows you to use CONTROLLINO_xx aliases in your sketch. Requires an RS232/485 transceiver. One Arduino will act as the Master while the other Arduino will be configured as the Slave. A good summary can also be found on Wikipedia. Enlighten your Arduino to be a Modbus master. #include <SimpleModbusMaster. In the modbus rtu master program, if I want to read the address 4113 and its function is 4, 2019, 4:14pm 4. Use software and hardware to test each application that you write. Modbus is an industrial communication protocol. Salah satu protokol komunikasi yang paling umum digunakan adalah Modbus, yang I'm trying to use the ModbusRTU. Does anyone know a library which can be used to implement it. I'm very new to Modbus, any help would be greatly appreciated Link to Modbus Library Rapidscada Documentation Uno R3 board as slave/server, Rapidscada as Hello, I want use Modbus RTU communication between Arduino DUE,s but what I can' t find Programming Questions. Networking, Protocols, and Devices. Programming. Hi to all! First time on the arduino forum and a total beginner regarding arduino modbus communication. My project goal is to test Modbus functionality by sending Information from an Allen-Bradley Micrologix 1100(1763-L16BWA)as a Modbus Master(Client) to the MKR through its 485 interface as a Modbus Slave(Server). It's not the preferred way to write data once. It is divided into two parts such as Modbus I've started to play with the Modbus stuff and managed to get it working in my own fashion with reading and searching on the net. Modbus RTU Master option. This array carries the data that is written from the master. Its robust design makes it versatile across diverse settings. its what ensures proper timing by waiting to set DE low again once the buffer is empty or transmission is hello, i am new to use modbus interference with arduino using RX/TX pin. V2. Maybe Right now i'm using Arduino Uno R3, the C25B TTL to RS485 module and a ABB M1M Meter with Modbus RTU communica Hi everyone, I'm working on a project that requires to read some holding registers from a Modbus RTU Slave. Using the Arduino Modbus RS485 boards, one master Arduino can communicate with Multiple Slave Using a Modbus polling program to figure these things out will allow you to integrate these findings into your PLC and save the headache of continually changing the PLC program to figure out how to communicate with the device. 36 37 Note: 38 The Arduino serial ring buffer is 128 bytes or 64 registers. I would like to be able to use this with Mach 3. I searched through and found several relevant libraries and examples but I have difficulties making any to work and it seems as if I'l need to put in much more work. ''' bobcousins February 5, 2024, Arduino Master Modbus Rtu max485. In this tutorial, we will explore how to interface an Arduino as a master with a Modbus RTU (RS485) sensor a Modbus RTU Master With Arduino in 5 Minutes Part 1: I start with the following question Arduino can be used in industrial aplicaiones? of course, using a This is an Arduino library that implements the master/client logic of the Modbus RTU protocol. 2: 781: May 6, 2021 Hello, I need your help for Modbus RTU I installed Modbus RTU library 2)open the Modbus slave example as my project 3)upload the project to Arduino mega2560. Go to repository. Any suggestions or advice would be really helpful Below is the code #include Home / Programming / Library / ModbusMaster . 5: 4123: May 6, 2021 modbus rtu arduino raspberry over usb. Alternative values can be used per requirements if needed. Each device on a Modbus communication has a unique address. Modbus is mostly used in In this tutorial the Arduino Uno is configured as Modbus Master by using Master Modbus Arduino coding with the help of Modbus Master library. Supports network transport (Modbus TCP) and Serial line/RS-485 (Modbus RTU). Link: GitHub - smarmengol/Modbus-Master-Slave-for-Arduino: Modbus Master-Slave library for Arduino. Also is it possible to obtain data from a PLC using modbus TCP/IP and send it to a Server on cloud using the same ethernet port? Please help. I wish to use Could you please help me with MODBUS library GitHub - emelianov/modbus-esp8266: Most complete Modbus library for Arduino. You can use this library over RS485 or RS232. Remember to set your slave address as 0 in the simulation software. RS-485 Modbus uses RS-485 for transmission lines. MODBUS communication is done by sending the value of A0 (ADC0) 10 modbus records using a potentiometer 100k variation is performed. The only one I could keep I'm programming two Opta RS485 for a demo with Arduino PLC IDE, one as Modbus RTU Master and the other one as Slave. Modbus RTU Communication using ModbusMaster Library. I Dear all, here is code for measuring string current using modbus protocol; I have used the standard modbus library to interface modbus protocol. Write "C" applications to implement Modbus master and slave functionality. I have to, because the device I want to talk to is using the modbus protocol. 59 KB) Hi, I want to implement a code for Modbus RTU over TCP/IP usng TM4C1294NCPDT launchpad. This library implements function codes 1 (Read Coils), 2 (Read Discrete Inputs), 3 (Read Holding Registers), 4 (Read Input Registers), 5 (Write Single Coil), 6 (Write Single Holding Register), 15 (Write Multiple Coils), and 16 (Write Multiple Holding ArduinoRS485-master. Jan123456 November 16, 2017, 10:35am 1. I am currently using a MKR1000 and I have a MKR485 Shield on it. The reason why I create new library because I've tried to use SimpleModbus to communicate with my HMI screen but it reported a lot of errors. Well until now I did not find an example that is plain simple to use. Even though the value of temp1, temp2, etc is correct, it is not being sent correctly. Modbus RTU Configuration. Hi everyone, I'm newbie in this forum, this is my first post, if I have any mistake, please help me to fix it! Thanks! I'm writing new Modbus RTU library for arduino (master and slave) based on SimpleModbus. All of the programs written in the course are freely downloadable and give you a perfect I am using below code but receiving 224 value in result instead of 0 but my modbus rtu drive is accepting commands What to do? #include <ModbusMaster. I start with the following question Arduino can be used in industrial aplicaiones? of course, using a common protocol used in the industry called Modbus Serial RTU in this case configured as Master. Maintainer: I have a sensor that sends data through Modbus RTU and I would like to communicate with it but I’m not sure how. 09/17/2024. . This is an Arduino library that implements the master/client logic of the Modbus RTU protocol. This command can be written in a single register, which is specified in Modbus RTU as function Hello everyone, this is my first post in Arduino Forum, and I am quite a beginner in using RS485 sensors, as I am having some trouble understanding Modbus RTU. I use Linux primarily and found this Free Modbus Slave Simulator and Test Tool which runs natively on Linux and Windows and may be of use to someone who reads this guide of yours. markd833: Great guide @einarbjorkman, I really hit the ground running thanks to your help. 2: 2595: A modbus TCP master/client simulation program and check that connection is working; A modbus RS485 slave/server simulation program. Allows you to connect Modbus RTU slaves (such as sensors, energy meters, HVAC devices) to Modbus TCP/UDP masters (such as home automation Hello everyone! Briefly introduction, I would like to communicate and test the following hardwares: 1- Omron CP1E (using an Option Port CP1W-CIF11) ; and 2- Arduino Nano using MAX485 RS485 transceiver. Communication. Several versions of the Modbus protocol exist such as Modbus RTU, Modbus ASCII, Modbus TCP and Modbus Plus. 3. 3. Im not to sure on how the talking actually happens between RS485 Master/Slave I understand that the master sends a request with an address and the slave identifies with the address and then sends data back to the master. The master is an Arduino UNO (or Mega 2560) that communicates to different slaves (the I need to set up a Modbus RTU MASTER communication network and also SLAVE RTU with ESP8266 12E (or F, whatever), but I couldn't find a good Modbus RTU library. The DUE is working as slave & installed MODSCAN software into PC. I'm currently working on a project where I will send DHT11 and SW420 sensor data use RS485 Module from slaves 1 and 2 (using Arduino Nano) to the master (Arduino Uno). h> #include <SoftwareSerial. It enables an Arduino or Arduino compatible board to send Modbus RTU requests to Modbus slave/server devices, and to process their responses. This library implements function codes 1 (Read Coils), 2 (Read Discrete Inputs), 3 (Read In the RS-485 Modbus network, there is one Master and 127 Slaves each with a unique address from 1 to 127. ModbusMaster. I have the following : A Schneider power meter with Modbus Using Arduino with Modbus RTU to read registers of Schneider power meter Acti 9. ModBus RTU; baud: 57600; Even Parity; 1 stop-bit; Sensors where i wanne read the data from are within the input register; The code for the Arduino master. I use this library GitHub - 4-20ma/ModbusMaster: Enlighten your Arduino to be a Modbus master Hardware: ESP8266 and MAX485 board. This library has some examples to Daftar Isi Artikel Mengenal Lebih Dekat: Komunikasi Modbus Master Arduino dengan Modbus Slave Menggunakan Protokol Modbus RTU RS485 Pendahuluan Dalam dunia automasi industri, komunikasi antar perangkat elektronik adalah inti dari operasi yang efisien dan terkoordinasi. I am using Modbusrtu. Inside the Arduino PLC IDE navigate to the left side panel and click on the "Resources" tab. Sensors . I cannot figure out if this is a problem . 3 binding. It is based on a controller-peripheral (formerly known as master-slave) architecture and communication between nodes is achieved with send request and read response type messages. A library that allows your Arduino board to communicate via Modbus protocol, acting as I ordered a sensor that measures three parameters at specific register addresses. Firstly I would like to thank everyone for taking your time to help me in this matter. I'm currently trying to use the SimpleModbusMaster library. There is a Modbus Master library created almost 8-9 years ago for implementing Modbus RTU Communication. Author: Doc Walker. So I have communication between these two devices, but it seems that data read from raspberry pi is I am trying to receive some data out of an modbus slave, the TX and RX pin on the RS485 are blinking while connected. I'm trying to read a voltage value in RapidScada from Arduino via Modbus RTU but I only get integers on the SCADA side when the Arduino is outputting floats. Can somebody help me how to build code which can operate with two or more slaves? I'm using Modbus. V0. Here I use the modbus RTU library from GitHub - smarmengol/Modbus-Master-Slave-for-Arduino: Modbus Master-Slave library for Arduino. The Arduino programming language Reference, organized into Functions, Enlighten your Arduino to be a Modbus master. Interconnect Arduino hardware with other add-on hardware. I haven't found any information about this on the forum, the internet, or anywhere else. 9). But I struggled several days with the modbus write function. Therefore, if you want to write single values to your slave, you should search for another Hello All, I am new to the Forum and mostly new to Arduino. Later try to solve above problem yourself Arduino Modbus RS485 Master and Slave– In this tutorial, you will learn how to communicate between two Arduino’s using Modbus Serial Communication protocol. Reading from the slave is no problem. Enables communication with Modbus slaves over RS232/485 (via RTU protocol). PC will work as MASTER. h library with SoftSerial. zip (7. I really appreciate the guidance and advices given here 🙂 I would like to use a RS485 based sensor with my I have been looking at so many different types of examples for Modbus RTU that I think i am missing MODBUS RTU master and slave. TCP Master/Client & RTU Slave/Server: Apologies if posted in the wrong place, first time. */ #include "ModbusRtu. Supports serial (RS-232, RS is that UIPEthernet library + ModbusIP uses about 60% arduino program memory, whereas with Ethercard + ModbusIP_ENC28J60 this value Arduino Modbus RTU Author: Juan Pablo Zometa, Samuel and Hey, I am trying to send int type data through MODBUS with arduino uno acting as the master and a slave MODBUS simulator on my PC. I have used modbus RTU library from arduino The device working fine with baud rate 9600; if i am changing baudrate to 19200 it get message timeout error first method i thought convert float to integer store in buffer of au16data[xx] au16data[1]=(int)(100*Current_Value1[0]); Second method divide float value individually ie int & float value & convert & store in buffer of two I need help with the steps to implement Modbus RTU on the OPTA using ladder or FBD programming. Communication . I use the arduino as master and the sensor as slave. Its got an RS485 interface (pin D9 controls the direction of flow). The Modbus RTU works by RS-485 which is a single cable multi-drop network, only the node assigned as the Master may initiate a command. It should be noted that Modbus is a software protocol and not a hardware protocol. An Arduino forum isn't the right place to ask questions not related to the Arduino. h I am able to read the Holding registers of a Hiking DDS238-2ZN/S power meter with a MKR1010 via TCP but somewhat slowly compared to using a direct Modbus RTU connection to the MK Hello, I try to make simple Modbud RTU, RS485 comunication between Arduino Uno (Slave), that measures temperature with DS18B20 and PC (Master). The same function returns a correct value if I change the data (see BYTE nr. Modbus-Master-Slave-for-Arduino library, to connect Openhab ModBus 2. 5: 699: January 23, 2023 Arduino Nano RS-485 Modbus slave to master write problem. I used a MAX485 interface to make the connection. 7. I only need to read two holding registers with 3 words each. This is an Arduino library that implements the master/client logic of the Modbus RTU protocol. The Arduino development board allows you to create very simple, but very powerful, Modbus master or slave devices through the use of relatively simple "C" programming. Hi There, I have built an arduino-based tool changer for a conventional 2-axis turning lathe machine. My goal is: PC sends order via Modbus RTU RS485 to start measure Arduino measures temperature Arduino sends measured data to PC Modbus RTU is needed, because next step is to change PC into PLC, long answer: I want to be able to read and write data from these devices from a remote site on a website. I am trying to implement the code given in This is like my 5th post or something, but I wanted to give back. Related topics Topic Replies Views Activity; NodeMCU as modbus RTU master. The detail instruction, code, wiring diagram, video tutorial, line Hi, after losing a full 2 days to this i think i found out the problem. i want to Read some parameters from the modbus which is connected to some energy meter. In this article, we will use Arduino Uno as both Master and Slave for serial communication. Choose the appropriate Arduino hardware. x. To get started I used the code I found at RS485 MODBUS Serial Communication using Arduino UNO as Slave Since I don't use the LCD screen, I deleted this part of the code. and please ensure that the above program is Right or not. h> #define MODBUS_DATA_TRANSACTION_PIN 8 SoftwareSerial mySerial(2,3); //Software Serial port For Arduino Uno 34 35 The modbus_update() method updates the holdingRegs register array and checks communication. zip Simplemodbusng-master. Rtu library with advanced example from Github. Im mostly stumped on how sending something like this => sendMSG(byte address1,byte address2,byte data_type,byte code1,byte Using Arduino Mega for Modbus RTU. If I have a tool change in the G-Codes ex. 4: 1064: May 8, 2022 Modbus problem between sensor and Arduino. The CP1E The diagram emphasizes the consistent Modbus RTU configuration across Arduino devices with the PLC IDE. For rpi I'm using pymodbus and for arduino this Google Code Archive - Long-term storage for Google Code Project Hosting. Arduino library for communicating via modbus with the Arduino acting as master . This is a program for the Windows platform. 09/23/2016. No matter the Modbus RTU specifics, the PLC program can operate seamlessly. From what I could tell, you can program it just like any other Arduino type board. 2: 138: September 29, 2024 ModbusRTU protocol - RS485 Attached program I have tested with my Arduino Due board. Hello everybody, I have looked up multiple modbus-libraries on Github and read the example-codes. Modbus Slave Simulator does offer much more functionality but its nice knowing there isn't just This library implements the Modbus protocol over two different types of transport: serial communication over RS485 with RTU (Remote Terminal Unit) or Ethernet and WiFi communication with TCP protocol. Please, maybe someone can help with it, so what would help is an example of how Modbus master and Modbus slave would be implemented. 2. Doc Walker. Important: Once you use the Modbus Mode to Master/Slave the RS-485 ports will be only dedicated to Modbus, so the RS-485 protocol is not accessible while using Modbus. The full details of the Modbus protocol can be found at modbus. Hello, I'm having some issues getting the esp32 running as a modbus tcp client. the simplemodbus Master library - we are talking about in this thread - is perfect for reading data over and over again. I've searched and can only seem to find Hey, I am trying to learn Modbus, so I have one arduino and raspberry Pi and they are connected via usb (yes without converters). I have a configuration: Master (Arduino MEGA ATmega2560), 2x MAX485 module (MAX485) and 1x Slave Good morning, I'm working on an Arduino project that requires a communication between Arduino and multiple pressure sensors. Mogaraghu December 17, 2019, 2:12pm 1. I want to establish Modbus RTU RS485 communication between PLC Schneider Electric TM241 (Master) and Arduino UNO (Slave). 8: 1036: August 12, 2023 Rs 485 transmitter connect with arduino. 2: 778: May 6, 2021 Help with Modbus RTU - RS485. Hello guys! I'm working on an arduino project that require bulletproof communication between few arduinos (up to 30 or more, up to 100m) in disruptive environment (like near frequency inverter). I tried many programs on the internet to get the kg information from the weight indicator I have and write it to the serial port, but I failed. jjfrrcnhaouiwbqirozyqbyhanmlxxkbadqmpdbfswgjpcsebjm